SP9021 Position Sensor Polarity Error Drive alarm 21
The polarity parameter setting of the position sensor is wrong. Check and correct the parameters. (Parameter No. 4000#0, 4001#4) If external encoder check timing belt near spindle
The polarity parameter setting of the position sensor is wrong.
Check and correct the parameters. (Parameter No. 4000#0, 4001#4)
If external encoder check timing belt near spindle
See lessHow do I troubleshoot the SP9020 Excess Offset Current V error in Fanuc machines?
SP9020 SSPA:20 EXCESS OFFSET CURRENT V Abnormality in an Spindle Amplifier component is detected. (The initial value for the V phase current detection circuit is abnormal.) Amplifier indicates 20 When encountering the SP9020 SSPA:20 Excess Offset Current V error message, indicating that there is anRead more
When encountering the SP9020 SSPA:20 Excess Offset Current V error message, indicating that there is an abnormality in a spindle amplifier component and that the initial value for the V phase current detection circuit is abnormal, it suggests an issue with the spindle amplifier’s ability to accurately detect and manage current in the V phase. Here’s how to troubleshoot and resolve this issue:
Steps to Troubleshoot and Resolve the SP9020 Error
How do I troubleshoot the SP9019 Excess Offset Current U error in Fanuc machines?
SP9019 SSPA:19 EXCESS OFFSET CURRENT U Abnormality in an Spindle Amplifier component is detected. (The initial value for the U phase current detection circuit is abnormal.) When encountering the SP9019 SSPA:19 Excess Offset Current U error message indicating that there is an abnormality in a spindleRead more
When encountering the SP9019 SSPA:19 Excess Offset Current U error message indicating that there is an abnormality in a spindle amplifier component and that the initial value for the U phase current detection circuit is abnormal, it suggests an issue with the spindle amplifier’s ability to detect and manage current properly. Here’s how to address this issue:
Steps to Troubleshoot and Resolve the Issue
How do I troubleshoot the SP9018 SUMCHECK error in the spindle alarm on Fanuc controllers?
Abnormality in an Spindle Amplifier control circuit component is detected. (Program ROM data is abnormal.) Replace the Spindle Amplifier control printed circuit board. When encountering an error stating "Abnormality in a Spindle Amplifier control circuit component is detected. (Program ROM data is aRead more
Abnormality in an Spindle Amplifier control circuit component is detected. (Program ROM data is abnormal.) Replace the Spindle Amplifier control printed circuit board.
When encountering an error stating “Abnormality in a Spindle Amplifier control circuit component is detected. (Program ROM data is abnormal.) Replace the Spindle Amplifier control printed circuit board”, it indicates a fault within the spindle amplifier’s control circuit, specifically related to the Program ROM data. Here’s how to address the issue:
Steps to Address the Issue
What should I check if I get an SP9017 Serial Spindle Alarm on my Fanuc controller?
Abnormality in spindle amplifier ID data is detected. Replace the Spindle Amplifier. Steps to Troubleshoot and Confirm the Cause Reboot the CNC: Power down the CNC completely, wait a few minutes, and power it back up. Sometimes, temporary system glitches cause ID reading errors that a restart can clRead more
Abnormality in spindle amplifier ID data is detected. Replace the Spindle Amplifier.
Steps to Troubleshoot and Confirm the Cause
How do I fix the Fanuc SP9016 SSPA:16 RAM error on my CNC machine?
Abnormality in an Spindle Amplifier control circuit component is detected. (RAM for external data is abnormal.) Replace the Spindle Amplifier control printed circuit board Troubleshooting Steps: Power Cycle and Reset: Turn off the machine, wait for a few minutes, and restart it to see if the error pRead more
Abnormality in an Spindle Amplifier control circuit component is detected. (RAM for external data is abnormal.) Replace the Spindle Amplifier control printed circuit board
Troubleshooting Steps:
What causes the Fanuc SP9015 Spindle Switching Fault?
Based on the information provided, here are descriptions for each step and related question concerning the Fanuc SP9015 SPINDLE SWITCHING FAULT: Check and correct the ladder sequence. This step involves examining the CNC machine's ladder logic to ensure that the sequence of operations is correctly pRead more
Based on the information provided, here are descriptions for each step and related question concerning the Fanuc SP9015 SPINDLE SWITCHING FAULT:
This step involves examining the CNC machine’s ladder logic to ensure that the sequence of operations is correctly programmed. An incorrect ladder sequence may lead to improper spindle switching and trigger the SP9015 fault.
The switching magnetic contactor (MC) may be faulty if it fails to engage or disengage properly. Replacing a defective MC can resolve issues where the mechanical switching is not occurring as expected, leading to the SP9015 fault.
An abnormal switch sequence during spindle or output switch operations indicates a potential issue in the control logic or hardware. Verifying and correcting this sequence is crucial to ensure proper machine operation and avoid the SP9015 fault.
If the status check signal of the switching MC does not align with the command being given, it suggests a discrepancy that can cause the machine to detect an error. This mismatch needs to be resolved to clear the SP9015 fault.
Each of these descriptions and questions addresses specific troubleshooting actions or considerations for resolving the SP9015 fault in Fanuc CNC systems.
See lessHow does the SP9014 SERIAL SPINDLE ALARM affect equipment performance?
SP9014 Serial Spindle Alarm If you're encountering the SP9014 Serial Spindle Alarm, it means that you are using a spindle amplifier that is not registered in the spindle software program. Don't worry, there's a simple solution to fix this issue. Upgrade the Spindle Software Program To resolve the SPRead more
SP9014 Serial Spindle Alarm
If you’re encountering the SP9014 Serial Spindle Alarm, it means that you are using a spindle amplifier that is not registered in the spindle software program. Don’t worry, there’s a simple solution to fix this issue.
Upgrade the Spindle Software Program
To resolve the SP9014 alarm, you need to upgrade the spindle software program. This upgrade will ensure that the spindle amplifier is correctly registered and recognized by the software.
Upgrading the spindle software program is a straightforward process. Here’s what you need to do:
Spindle Amplifier Indication – 14
While dealing with the SP9014 alarm, you may also come across the spindle amplifier indication with 14 points. This indication refers to specific diagnostic points related to the spindle amplifier.
To troubleshoot the spindle amplifier indication – 14 points, it’s recommended to refer to the manufacturer’s documentation or contact their support team for detailed guidance. They will be able to provide you with the necessary information to resolve the issue.
Remember, upgrading the spindle software program should address the SP9014 alarm, but if you’re still experiencing any difficulties, don’t hesitate to seek assistance from the manufacturer or a qualified technician.
What causes trigger the SP9013 SSPA:13 CPU DATA MEMORY FAULT error message?
SP9013 SSPA:13 CPU Data Memory Fault Abnormality If you are encountering the error message "SP9013 SSPA:13 CPU Data Memory Fault Abnormality" in your spindle amplifier control circuit, it means that there is a problem with the internal RAM. This issue can be resolved by replacing the spindle amplifiRead more
SP9013 SSPA:13 CPU Data Memory Fault Abnormality
If you are encountering the error message “SP9013 SSPA:13 CPU Data Memory Fault Abnormality” in your spindle amplifier control circuit, it means that there is a problem with the internal RAM. This issue can be resolved by replacing the spindle amplifier control printed circuit board.
Replacing the Spindle Amplifier Control Printed Circuit Board
To fix the abnormality in the spindle amplifier control circuit, you will need to replace the faulty printed circuit board. Here are the steps you can follow:
By following these steps and replacing the spindle amplifier control printed circuit board, you should be able to fix the abnormality and get your machine running smoothly again.
What causes trigger the SP9012 SSPA:12 OVERCURRENT POWER CIRCUIT error message?
SP9012 SSPA:12 Overcurrent Power Circuit If you are experiencing abnormally high motor current on your SP9012 SSPA:12, there are a few potential causes that you can investigate. Poor Motor Insulation One possible cause of the high motor current is poor motor insulation. To check the motor insulationRead more
SP9012 SSPA:12 Overcurrent Power Circuit
If you are experiencing abnormally high motor current on your SP9012 SSPA:12, there are a few potential causes that you can investigate.
Poor Motor Insulation
One possible cause of the high motor current is poor motor insulation. To check the motor insulation status, follow these steps:
Motor-Specific Parameter Mismatch
Another potential cause of the issue is a mismatch between a motor-specific parameter and the motor model. To address this, consider the following steps:
Spindle Amplifier Indication 12
If you are seeing the spindle amplifier indication 12, it could be related to the overcurrent power circuit issue. To troubleshoot this, follow these steps:
By following these steps, you should be able to identify and address the cause of the abnormally high motor current on your SP9012 SSPA:12.