Unlocking Tips to Fix SP9011 SSPA:11 Overvolt Power Circuit Errors
SP9011 SSPA:11 Overvolt Power Circuit An overvoltage of the DC link section of the power supply (PS) has been detected, resulting in a power supply alarm indication of 7. This indicates a power supply selection error, where the maximum output specification of the power supply (PS) has been exceeded.Read more
SP9011 SSPA:11 Overvolt Power Circuit
An overvoltage of the DC link section of the power supply (PS) has been detected, resulting in a power supply alarm indication of 7. This indicates a power supply selection error, where the maximum output specification of the power supply (PS) has been exceeded.
Possible Solutions
Amplifier Indication
The amplifier indication 11 refers to the beta amplifier (drive) of the system. This indicates a specific issue related to the amplifier’s operation.
The alpha power amplifier indication 07 points to another specific issue related to the power amplifier. Both indications may be related to the overvolt power circuit problem.
It is recommended to consult the system manual or contact technical support for further assistance in troubleshooting and resolving the issues with the power circuit and amplifiers.
See lessWhat causes Fanuc alarm SP9010 SSPA:10 LOW VOLT INPUT POWER?
A drop in the input power voltage in the spindle amplifier is detected. 1 The input power voltage in the Power Supply (PS) is too low. 2 The power cable between amplifiers is abnormal. 3 The spindle amplifier is abnormal. Spindle Amplifier indication 10
A drop in the input power voltage in the spindle amplifier is detected.
1 The input power voltage in the Power Supply (PS) is too low.
2 The power cable between amplifiers is abnormal.
3 The spindle amplifier is abnormal.
Spindle Amplifier indication 10
See lessFanuc SP9009 SSPA:09 OVERHEAT MAIN CIRCUIT error message?
The temperature in the power semiconductor cooling radiator is abnormally high. 1 Improve the heat sink cooling status. 2 If the external radiator cooling fan stops, replace the Spindle Amplifier. Spindle Amplifier indication 09
The temperature in the power semiconductor cooling radiator is abnormally high.
1 Improve the heat sink cooling status.
2 If the external radiator cooling fan stops, replace the Spindle Amplifier.
Spindle Amplifier indication 09
See lessFanuc SP9007 SSPA:07 OVER SPEED" error message?
The motor speed has exceeded 115% of its rated speed. When the spindle axis was in position control mode, positional deviations were accumulated excessively (SFR and SRV were turned off during spindle synchronization.) Check for a sequence error. (For example, check whether spindle synchronization wRead more
The motor speed has exceeded 115% of its rated speed. When the spindle axis was in position control mode, positional deviations were accumulated excessively (SFR and SRV were turned off during spindle synchronization.)
Check for a sequence error. (For example, check whether spindle synchronization was specified when the spindle could not be turned.)
Spindle Amplifier indication 07
See lessFanuc alarm SP9006 THERMAL SENSOR DISCONNECT
The temperature sensor of the motor is disconnected 1 Check and correct the parameter. 2 Replace the feedback cable. Spindle Amplifier indication 06
The temperature sensor of the motor is disconnected
1 Check and correct the parameter.
2 Replace the feedback cable.
Spindle Amplifier indication 06
See lessCan the "SP9004 SSPA:04 POWER SUPPLY ERROR" be resolved without professional assistance?
The Power Supply (PS) found a missing power supply phase. (Power Supply (PS) alarm E) Check the voltage of the power input to the Power Supply (PS) and the connection status. Spindle Amplifier indication 4
The Power Supply (PS) found a missing power supply phase. (Power Supply (PS) alarm E)
Check the voltage of the power input to the Power Supply (PS) and the connection status.
Spindle Amplifier indication 4
See lessHow to Resolve Fanuc SP9003 Alarm?
SP9003 SSPA:03 DC-LINK FUSE IS BROKEN The Power Supply (PS) becomes ready (“00” is indicated), but the DC link voltage is too low in the Spindle Amplifier. The fuse in the DC link section in the Spindle Amplifier is blown. (The power device is damaged or the motor is ground-fault.) 1 Replace the SpiRead more
SP9003 SSPA:03 DC-LINK FUSE IS BROKEN
The Power Supply (PS) becomes ready (“00” is indicated), but the DC link voltage is too low in the Spindle Amplifier. The fuse in the DC link section in the Spindle Amplifier is blown. (The power device is damaged or the motor is ground-fault.)
1 Replace the Spindle Amplifier.
2 Check the motor insulation status.
Spindle Amplifier indication 3
See lessHow to solve fanuc alarm SP9002 ?
Excessive Motor Load Torque In the SP9002 SSPA:02, one of the common issues faced is the inability of the motor speed to follow a specified speed. This is often due to an excessive motor load torque being detected. To resolve this issue, there are a few steps that can be taken: 1. Check and CorrectRead more
Excessive Motor Load Torque
In the SP9002 SSPA:02, one of the common issues faced is the inability of the motor speed to follow a specified speed. This is often due to an excessive motor load torque being detected. To resolve this issue, there are a few steps that can be taken:
1. Check and Correct Cutting Conditions
The first step is to check and correct the cutting conditions to decrease the load on the motor. This can be done by adjusting parameters such as feed rate, depth of cut, and cutting speed. By optimizing these parameters, the load on the motor can be reduced, allowing it to better match the specified speed.
2. Correct Parameter No. 4082
Another possible solution is to correct Parameter No. 4082, which controls the acceleration and deceleration time. If the acceleration/deceleration time is insufficient, it can cause the motor speed to deviate from the specified speed. By adjusting this parameter, you can ensure that the motor has enough time to reach and maintain the desired speed.
By following these steps, you can address the issue of the motor speed not being able to follow a specified speed and the detection of excessive motor load torque. It is important to carefully analyze the cutting conditions and adjust the relevant parameters to optimize the motor performance.
How to solve Fanuc Spindle Alarm SP9001?
There can be several reasons why the Fanuc Spindle Alarm SP9001 may occur. Some possible causes include: Problems with the spindle motor or drive Electrical issues, such as a loose connection or faulty wiring Malfunctioning sensors or encoders Problems with the spindle control unit or software If yoRead more
There can be several reasons why the Fanuc Spindle Alarm SP9001 may occur. Some possible causes include:
If you encounter the Fanuc Spindle Alarm SP9001, here are some steps you can take to troubleshoot the issue:
Fixing the Fanuc Spindle Alarm SP9001 may require technical expertise and knowledge of CNC machines. It is recommended to consult a qualified technician or contact the manufacturer’s support for assistance. Attempting to fix the issue without the necessary skills and knowledge may result in further damage to the machine.