Lost your password? Please enter your email address. You will receive a link and will create a new password via email.
Please briefly explain why you feel this question should be reported.
Please briefly explain why you feel this answer should be reported.
Please briefly explain why you feel this user should be reported.
We want to connect the people who have knowledge to the people who need it, to bring together people with different perspectives so they can understand each other better, and to empower everyone to share their knowledge.
What is the purpose of the F0.4 signal in a FANUC
Signal : F0.4 Symbol : SPL Description : Feed hold signal Detail : CNC will inform the PLC that feed hold is given by user. The F0.4 (SPL) flag is typically activated when the operator presses the feed hold button on the CNC panel to temporarily stop the machine’s motion. In response, the PLC wouldRead more
Signal : F0.4
Symbol : SPL
Description : Feed hold signal
Detail : CNC will inform the PLC that feed hold is given by user.
The F0.4 (SPL) flag is typically activated when the operator presses the feed hold button on the CNC panel to temporarily stop the machine’s motion. In response, the PLC would typically:
What is the purpose of the F0.0 signal in a FANUC PLC ladder program?
Signal : F0.0 Symbol : RWD Description : Rewind signal Detail : CNC will inform the PLC that reset and rewind command is given by user. When the F0.0 (RWD) signal is activated, the PLC is expected to initiate actions that are defined for a reset and rewind operation. These actions might include: CleRead more
Signal : F0.0
Symbol : RWD
Description : Rewind signal
Detail : CNC will inform the PLC that reset and rewind command is given by user.
When the F0.0 (RWD) signal is activated, the PLC is expected to initiate actions that are defined for a reset and rewind operation. These actions might include:
SP9021 Position Sensor Polarity Error Drive alarm 21
The polarity parameter setting of the position sensor is wrong. Check and correct the parameters. (Parameter No. 4000#0, 4001#4) If external encoder check timing belt near spindle
The polarity parameter setting of the position sensor is wrong.
Check and correct the parameters. (Parameter No. 4000#0, 4001#4)
If external encoder check timing belt near spindle
See lessHow do I troubleshoot the SP9020 Excess Offset Current V error in Fanuc machines?
SP9020 SSPA:20 EXCESS OFFSET CURRENT V Abnormality in an Spindle Amplifier component is detected. (The initial value for the V phase current detection circuit is abnormal.) Amplifier indicates 20 When encountering the SP9020 SSPA:20 Excess Offset Current V error message, indicating that there is anRead more
When encountering the SP9020 SSPA:20 Excess Offset Current V error message, indicating that there is an abnormality in a spindle amplifier component and that the initial value for the V phase current detection circuit is abnormal, it suggests an issue with the spindle amplifier’s ability to accurately detect and manage current in the V phase. Here’s how to troubleshoot and resolve this issue:
Steps to Troubleshoot and Resolve the SP9020 Error
How do I troubleshoot the SP9019 Excess Offset Current U error in Fanuc machines?
SP9019 SSPA:19 EXCESS OFFSET CURRENT U Abnormality in an Spindle Amplifier component is detected. (The initial value for the U phase current detection circuit is abnormal.) When encountering the SP9019 SSPA:19 Excess Offset Current U error message indicating that there is an abnormality in a spindleRead more
When encountering the SP9019 SSPA:19 Excess Offset Current U error message indicating that there is an abnormality in a spindle amplifier component and that the initial value for the U phase current detection circuit is abnormal, it suggests an issue with the spindle amplifier’s ability to detect and manage current properly. Here’s how to address this issue:
Steps to Troubleshoot and Resolve the Issue
How do I troubleshoot the SP9018 SUMCHECK error in the spindle alarm on Fanuc controllers?
Abnormality in an Spindle Amplifier control circuit component is detected. (Program ROM data is abnormal.) Replace the Spindle Amplifier control printed circuit board. When encountering an error stating "Abnormality in a Spindle Amplifier control circuit component is detected. (Program ROM data is aRead more
Abnormality in an Spindle Amplifier control circuit component is detected. (Program ROM data is abnormal.) Replace the Spindle Amplifier control printed circuit board.
When encountering an error stating “Abnormality in a Spindle Amplifier control circuit component is detected. (Program ROM data is abnormal.) Replace the Spindle Amplifier control printed circuit board”, it indicates a fault within the spindle amplifier’s control circuit, specifically related to the Program ROM data. Here’s how to address the issue:
Steps to Address the Issue
What should I check if I get an SP9017 Serial Spindle Alarm on my Fanuc controller?
Abnormality in spindle amplifier ID data is detected. Replace the Spindle Amplifier. Steps to Troubleshoot and Confirm the Cause Reboot the CNC: Power down the CNC completely, wait a few minutes, and power it back up. Sometimes, temporary system glitches cause ID reading errors that a restart can clRead more
Abnormality in spindle amplifier ID data is detected. Replace the Spindle Amplifier.
Steps to Troubleshoot and Confirm the Cause