What causes trigger the SP9013 SSPA:13 CPU DATA MEMORY FAULT error message?
SP9013 SSPA:13 CPU Data Memory Fault Abnormality If you are encountering the error message "SP9013 SSPA:13 CPU Data Memory Fault Abnormality" in your spindle amplifier control circuit, it means that there is a problem with the internal RAM. This issue can be resolved by replacing the spindle amplifiRead more
SP9013 SSPA:13 CPU Data Memory Fault Abnormality
If you are encountering the error message “SP9013 SSPA:13 CPU Data Memory Fault Abnormality” in your spindle amplifier control circuit, it means that there is a problem with the internal RAM. This issue can be resolved by replacing the spindle amplifier control printed circuit board.
Replacing the Spindle Amplifier Control Printed Circuit Board
To fix the abnormality in the spindle amplifier control circuit, you will need to replace the faulty printed circuit board. Here are the steps you can follow:
By following these steps and replacing the spindle amplifier control printed circuit board, you should be able to fix the abnormality and get your machine running smoothly again.
What causes trigger the SP9012 SSPA:12 OVERCURRENT POWER CIRCUIT error message?
SP9012 SSPA:12 Overcurrent Power Circuit If you are experiencing abnormally high motor current on your SP9012 SSPA:12, there are a few potential causes that you can investigate. Poor Motor Insulation One possible cause of the high motor current is poor motor insulation. To check the motor insulationRead more
SP9012 SSPA:12 Overcurrent Power Circuit
If you are experiencing abnormally high motor current on your SP9012 SSPA:12, there are a few potential causes that you can investigate.
Poor Motor Insulation
One possible cause of the high motor current is poor motor insulation. To check the motor insulation status, follow these steps:
Motor-Specific Parameter Mismatch
Another potential cause of the issue is a mismatch between a motor-specific parameter and the motor model. To address this, consider the following steps:
Spindle Amplifier Indication 12
If you are seeing the spindle amplifier indication 12, it could be related to the overcurrent power circuit issue. To troubleshoot this, follow these steps:
By following these steps, you should be able to identify and address the cause of the abnormally high motor current on your SP9012 SSPA:12.
Unlocking Tips to Fix SP9011 SSPA:11 Overvolt Power Circuit Errors
SP9011 SSPA:11 Overvolt Power Circuit An overvoltage of the DC link section of the power supply (PS) has been detected, resulting in a power supply alarm indication of 7. This indicates a power supply selection error, where the maximum output specification of the power supply (PS) has been exceeded.Read more
SP9011 SSPA:11 Overvolt Power Circuit
An overvoltage of the DC link section of the power supply (PS) has been detected, resulting in a power supply alarm indication of 7. This indicates a power supply selection error, where the maximum output specification of the power supply (PS) has been exceeded.
Possible Solutions
Amplifier Indication
The amplifier indication 11 refers to the beta amplifier (drive) of the system. This indicates a specific issue related to the amplifier’s operation.
The alpha power amplifier indication 07 points to another specific issue related to the power amplifier. Both indications may be related to the overvolt power circuit problem.
It is recommended to consult the system manual or contact technical support for further assistance in troubleshooting and resolving the issues with the power circuit and amplifiers.
See lessWhat causes Fanuc alarm SP9010 SSPA:10 LOW VOLT INPUT POWER?
A drop in the input power voltage in the spindle amplifier is detected. 1 The input power voltage in the Power Supply (PS) is too low. 2 The power cable between amplifiers is abnormal. 3 The spindle amplifier is abnormal. Spindle Amplifier indication 10
A drop in the input power voltage in the spindle amplifier is detected.
1 The input power voltage in the Power Supply (PS) is too low.
2 The power cable between amplifiers is abnormal.
3 The spindle amplifier is abnormal.
Spindle Amplifier indication 10
See lessFanuc SP9009 SSPA:09 OVERHEAT MAIN CIRCUIT error message?
The temperature in the power semiconductor cooling radiator is abnormally high. 1 Improve the heat sink cooling status. 2 If the external radiator cooling fan stops, replace the Spindle Amplifier. Spindle Amplifier indication 09
The temperature in the power semiconductor cooling radiator is abnormally high.
1 Improve the heat sink cooling status.
2 If the external radiator cooling fan stops, replace the Spindle Amplifier.
Spindle Amplifier indication 09
See lessFanuc SP9007 SSPA:07 OVER SPEED" error message?
The motor speed has exceeded 115% of its rated speed. When the spindle axis was in position control mode, positional deviations were accumulated excessively (SFR and SRV were turned off during spindle synchronization.) Check for a sequence error. (For example, check whether spindle synchronization wRead more
The motor speed has exceeded 115% of its rated speed. When the spindle axis was in position control mode, positional deviations were accumulated excessively (SFR and SRV were turned off during spindle synchronization.)
Check for a sequence error. (For example, check whether spindle synchronization was specified when the spindle could not be turned.)
Spindle Amplifier indication 07
See lessFanuc alarm SP9006 THERMAL SENSOR DISCONNECT
The temperature sensor of the motor is disconnected 1 Check and correct the parameter. 2 Replace the feedback cable. Spindle Amplifier indication 06
The temperature sensor of the motor is disconnected
1 Check and correct the parameter.
2 Replace the feedback cable.
Spindle Amplifier indication 06
See lessCan the "SP9004 SSPA:04 POWER SUPPLY ERROR" be resolved without professional assistance?
The Power Supply (PS) found a missing power supply phase. (Power Supply (PS) alarm E) Check the voltage of the power input to the Power Supply (PS) and the connection status. Spindle Amplifier indication 4
The Power Supply (PS) found a missing power supply phase. (Power Supply (PS) alarm E)
Check the voltage of the power input to the Power Supply (PS) and the connection status.
Spindle Amplifier indication 4
See lessHow to Resolve Fanuc SP9003 Alarm?
SP9003 SSPA:03 DC-LINK FUSE IS BROKEN The Power Supply (PS) becomes ready (“00” is indicated), but the DC link voltage is too low in the Spindle Amplifier. The fuse in the DC link section in the Spindle Amplifier is blown. (The power device is damaged or the motor is ground-fault.) 1 Replace the SpiRead more
SP9003 SSPA:03 DC-LINK FUSE IS BROKEN
The Power Supply (PS) becomes ready (“00” is indicated), but the DC link voltage is too low in the Spindle Amplifier. The fuse in the DC link section in the Spindle Amplifier is blown. (The power device is damaged or the motor is ground-fault.)
1 Replace the Spindle Amplifier.
2 Check the motor insulation status.
Spindle Amplifier indication 3
See lessHow to solve Fanuc Spindle Alarm SP9001?
SP9001 SSPA:01 MOTOR OVERHEAT The internal temperature of the spindle motor exceeds the specified level. The motor is used in excess of the continuous rating, or the cooling component is abnormal. 1 Check and correct the peripheral temperature and load status. 2 If the cooling fan stops, replace it
SP9001 SSPA:01 MOTOR OVERHEAT
The internal temperature of the spindle motor exceeds the specified level. The motor is used in excess of the continuous rating, or the cooling component is abnormal.
1 Check and correct the peripheral temperature and load status.
2 If the cooling fan stops, replace it